Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results

J Thorac Cardiovasc Surg. 2012 Dec;144(6):1372-9; discussion 1379-80. doi: 10.1016/j.jtcvs.2012.07.104.

Abstract

Objective: Transcatheter aortic valve implantation has been used to treat high-risk patients with bioprosthetic valve degeneration (valve-in-valve). We report our experience with transcatheter aortic valve implantation in the treatment of degenerated biologic aortic valve prostheses and discuss factors that can influence the outcome.

Methods: From February 2009 to October 2011, 278 patients underwent transcatheter aortic valve implantation, of whom 23 underwent a valve-in-valve procedure with the Edwards Sapien valve to treat a failing bioprostheses in the aortic position. Eight of these valves were stentless bioprostheses. Thirteen patients had valve failure resulting predominantly from stenosis, and the remaining resulting from regurgitation.

Results: Mean age was 76.9 ± 14.4 years. The mean logistic EuroSCORE was 31.8% ± 20.3% and the Society of Thoracic Surgeons score was 7.6% ± 5.4%. All patients were New York Heart Association class III or IV. The majority of the operations (21/23) were performed via the transapical route. Procedural success was 100%, although 1 patient with a degenerated homograft needed immediate placement of a second valve because of low placement of the first. The reduction in the mean gradient was 31.2 ± 17.06 mm Hg to 9.13 ± 4.9 mm Hg. In those patients with predominant aortic regurgitation (9/23), reduction in aortic regurgitation was achieved in all. The median length of stay was 11.7 days (range, 3-44 days). In-hospital and/or 30-day mortality was 0%.

Conclusions: Valve-in-valve is a safe and feasible alternative to treat high-risk patients with failing aortic bioprostheses. The early results are excellent, with improvement seen in hemodynamics.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Insufficiency / etiology
  • Aortic Valve Insufficiency / physiopathology
  • Aortic Valve Insufficiency / therapy*
  • Aortic Valve Stenosis / etiology
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / therapy*
  • Bioprosthesis*
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Humans
  • Length of Stay
  • Male
  • Middle Aged
  • Patient Selection
  • Prosthesis Design
  • Prosthesis Failure
  • Risk Assessment
  • Risk Factors
  • Time Factors