How Much Negative Pressure Are We Generating During Thoracentesis?

Abdul Hamid Alraiyes, Fayez Kheir, Kassem Harris and Thomas R. Gildea
Ochsner Journal June 2017, 17 (2) 138-140;
Abdul Hamid Alraiyes
1Interventional Pulmonary Section, Department of Medicine, Roswell Park Cancer Institute and Division of Pulmonary, Critical Care, and Sleep Medicine, Department of Medicine, University at Buffalo, State University of New York, Buffalo, NY
MD, FCCP
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Fayez Kheir
2Division of Pulmonary Diseases, Critical Care and Environmental Medicine, Tulane University Health Sciences Center, New Orleans, LA
MD, MSCR
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kassem Harris
1Interventional Pulmonary Section, Department of Medicine, Roswell Park Cancer Institute and Division of Pulmonary, Critical Care, and Sleep Medicine, Department of Medicine, University at Buffalo, State University of New York, Buffalo, NY
MD, FCCP
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thomas R. Gildea
3Pulmonary, Allergy and Critical Care Medicine, Respiratory Institute, Cleveland Clinic Foundation, Cleveland, OH
MD, FCCP
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

TO THE EDITOR

Handheld digital pleural manometers (DPMs) are used to measure pleural pressure during thoracentesis. Lee et al demonstrated concordance between pleural pressure measurements done with a DPM and with an electronic transducer manometer.1

Only static intrathoracic pressure can be measured with the DPM. Pleural pressure is usually measured at the beginning of the thoracentesis (opening pressure), after removal of 240 cc of fluid, and at the end of the thoracentesis (closing pressure). To our knowledge, no published studies document the negative pressure that occurs during the actual drainage. This letter focuses on the difference between the negative pressures generated with manual intermittent suction (MIS) vs the negative pressure bottle (NPB).

CASE REPORT

A 73-year-old male with a history of stage IV adenocarcinoma of the lung presented with progressive shortness of breath. Thoracic ultrasound examination demonstrated a large right pleural effusion. Ultrasound-assisted right-side thoracentesis was performed, and a DPM was used to measure pressures during the procedure. Three static pleural pressure measurements were assessed: the opening pressure, the pressure after the removal of 240 cc of pleural fluid, and the closing pressure. An NPB was used, and a total of 800 cc of pleural fluid was removed. No signs of lung entrapment were evident. Thoracic ultrasound confirmed the total removal of the fluid and the presence of pleural sliding at the conclusion of the procedure. The patient tolerated the procedure, confirmed improvement of his respiratory symptoms, and denied any chest pain or cough. A week later, the patient presented with dyspnea on exertion and reported the feeling of pleural fluid accumulation. Thoracic ultrasound confirmed reformation of the pleural fluid, and 760 cc of fluid was removed using a manual 60-cc suction syringe. As during the previous procedure, 3 pleural pressure measurements were performed and revealed the absence of lung entrapment. On both occasions, we measured the negative pressure generated by the suction device. The negative pressure generated by the NPB started at approximately –115 cm H2O. Following the removal of 800 cc of fluid, the bottle pressure was approximately –75 cm H2O (Figure 1). On the other hand, when MIS was performed with a 60-cc syringe, the negative pressure was approximately –250 cm H2O each time with a fully pulled syringe (Figure 2). Despite the large difference between the negative pressures generated in each method, we saw no difference in the outcomes (Table).

Figure 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1.

Graph demonstrates the difference in negative pressure generated by a negative pressure bottle in relation to the volume of fluid removed while performing thoracentesis. On the right, a digital pleural manometer shows the negative pressure measurement at the start and at the end of the procedure.

Figure 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2.

Graph demonstrates the difference in negative pressure generated by manual intermittent suction with a 60-cc syringe (13 full 60-cc syringe suctions) in relation to the volume of fluid removed while performing thoracentesis. On the right, a digital pleural manometer shows the measurement of negative pressure at each full syringe suction.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table.

Intrathoracic Manometry Measurement while Using Negative Pressure Bottle and Manual Intermittent Suction

DISCUSSION

The DPM is a new tool that can measure pleural pressure during thoracentesis.1,2 The DPM is especially useful for patients with a high risk of expansion pulmonary edema or with lung entrapment.3 Young patients with large pleural effusion (>3 L) and more than 7 days' duration of lung collapse are at risk for developing expansion pulmonary edema.4,5 Obtaining static measurements of the pleural pressure while performing thoracentesis can provide information about the intrathoracic pressure. The measurements identify any sudden drop in the intrathoracic pressure and provide an early sign of lung entrapment. Our patient did not have any signs of lung entrapment during either procedure.

The amount of negative pressure generated by the NPB and MIS during the fluid removal process is significantly different. Although we saw no difference in the outcomes at the end of each procedure, the amount of negative pressure generated with MIS exceeded the negative pressure generated by the NPB by approximately 100 cm H2O with each syringe filling. On the other hand, the negative pressure generated by the NPB is a continuous negative pressure throughout fluid drainage that is inversely reduced by the volume removed. One of the factors that can contribute to the development of expansion pulmonary edema is the speed of the fluid removal. Considering both methods, the negative pressure generated by MIS can reach approximately –250 cm H2O with full syringe expansion and can cause more rapid fluid removal. Also, MIS can cause intermittent fluctuations in the intrathoracic pressure. To avoid the rapid removal of fluid and pressure fluctuations while using MIS, a gentle manual negative pressure can be applied.

The outcomes of both procedures did not show that one method was superior to the other. However, the NPB method is less cost effective than MIS because of the price of the bottles.

Our findings are an eye-opener about the amount of pressure generated with manual fluid removal.6 However, the real negative pressure generated by each method cannot be confirmed by static intermittent measurement of the pleural pressure. Intrathoracic pressure should be continuously measured to obtain the real correlation between the negative pressure generated and the pleural pressure.

  • © Academic Division of Ochsner Clinic Foundation

REFERENCES

  1. ↵
    1. Lee HJ,
    2. Yarmus L,
    3. Kidd D,
    4. et al.
    Comparison of pleural pressure measuring instruments. Chest. 2014 10; 146 4: 1007- 1012. doi: 10.1378/chest.13-3004. pmid:24853674
    OpenUrlCrossRefPubMed
  2. ↵
    1. Folch E,
    2. Mahajan A,
    3. Majid A
    Pleural manometry: ready for prime time. J Bronchology Interv Pulmonol. 2013 10; 20 4: 297- 298. doi: 10.1097/LBR.0000000000000019. pmid:24162110
    OpenUrlCrossRefPubMed
  3. ↵
    1. Pannu J,
    2. DePew ZS,
    3. Mullon JJ,
    4. Daniels CE,
    5. Hagen CE,
    6. Maldonado F
    Impact of pleural manometry on the development of chest discomfort during thoracentesis: a symptom-based study. J Bronchology Interv Pulmonol. 2014 10; 21 4: 306- 313. doi: 10.1097/LBR.0000000000000095. pmid:25321449
    OpenUrlCrossRefPubMed
  4. ↵
    1. Kasmani R,
    2. Irani F,
    3. Okoli K,
    4. Mahajan V
    Re-expansion pulmonary edema following thoracentesis. CMAJ. 2010 12 14; 182 18: 2000- 2002. doi: 10.1503/cmaj.090672. pmid:20643838
    OpenUrlFREE Full Text
  5. ↵
    1. Boshuizen RC,
    2. Sinaasappel M,
    3. Vincent AD,
    4. Goldfinger V,
    5. Farag S,
    6. van den Heuvel MM
    Pleural pressure swing and lung expansion after malignant pleural effusion drainage: the benefits of high-temporal resolution pleural manometry. J Bronchology Interv Pulmonol. 2013 7; 20 3: 200- 205. doi: 10.1097/LBR.0b013e31829af168. pmid:23857193
    OpenUrlCrossRefPubMed
  6. ↵
    1. Salamonsen M,
    2. Ware R,
    3. Fielding D
    A new method for performing continuous manometry during pleural effusion drainage. Respiration. 2014; 88 1: 61- 66. doi: 10.1159/000358842. pmid:24820119
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Ochsner Journal
Vol. 17, Issue 2
Jun 2017
  • Table of Contents
  • Index by author
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on Ochsner Journal.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
How Much Negative Pressure Are We Generating During Thoracentesis?
(Your Name) has sent you a message from Ochsner Journal
(Your Name) thought you would like to see the Ochsner Journal web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
How Much Negative Pressure Are We Generating During Thoracentesis?
Abdul Hamid Alraiyes, Fayez Kheir, Kassem Harris, Thomas R. Gildea
Ochsner Journal Jun 2017, 17 (2) 138-140;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
How Much Negative Pressure Are We Generating During Thoracentesis?
Abdul Hamid Alraiyes, Fayez Kheir, Kassem Harris, Thomas R. Gildea
Ochsner Journal Jun 2017, 17 (2) 138-140;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • TO THE EDITOR
    • CASE REPORT
    • DISCUSSION
    • REFERENCES
  • Figures & Data
  • References
  • Info & Metrics
  • PDF

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Reply to “Comment on ‘Pneumocystis jirovecii Pneumonia in Patients Treated for Solid Organ Malignancy’ ”
  • Comment on “Pneumocystis jirovecii Pneumonia in Patients Treated for Solid Organ Malignancy”
  • Reply to “The SARS-COV Pandemic Does Not Absolve From Solid Medical Trade”
Show more LETTERS TO THE EDITOR

Similar Articles

Ochsner Journal Blog

Current Post

Be Careful Where You Publish

Our Content

  • Home
  • Current Issue
  • Ahead of Print
  • Archive
  • Featured Contributors
  • Ochsner Journal Blog
  • Archive at PubMed Central

Information & Forms

  • Instructions for Authors
  • Instructions for Reviewers
  • Submission Checklist
  • FAQ
  • License for Publishing-Author Attestation
  • Patient Consent Form
  • Submit a Manuscript

Services & Contacts

  • Permissions
  • Sign up for our electronic table of contents
  • Feedback Form
  • Contact Us

About Us

  • Editorial Board
  • About the Ochsner Journal
  • Ochsner Health
  • University of Queensland-Ochsner Clinical School
  • Alliance of Independent Academic Medical Centers

© 2025 Ochsner Clinic Foundation

Powered by HighWire